1 概況···············································3
2 技術(shù)參數(shù)及說明····································3
3 設(shè)計標準及依據(jù)····································4
4 方案設(shè)計···········································4
4.1墻體隔聲設(shè)計··································4
4.2地面隔聲隔振設(shè)計······························4
4.3室內(nèi)通風(fēng)消音設(shè)計······························5
4.4室內(nèi)吸聲內(nèi)飾設(shè)計······························5
4.5隔音觀察窗的設(shè)計······························6
4.6門的隔音設(shè)計··································6
4.7室內(nèi)地面環(huán)保設(shè)計·····························7
4.8 室內(nèi)照明設(shè)計·································7
5 設(shè)計效果··········································7
6 聲學(xué)材料性能·····································7
6.1高強度隔聲板·································7
6.2橡膠阻尼減振墊·······························7
6.3玻璃棉········································7
7 主要材料明細·····································8
8 施工說明及驗收標準······························8
9 ***服務(wù)·········································8
10 工程預(yù)算·········································9
1 概況
本項目為***聽力檢測測聽室的設(shè)計方案。該測聽室對聲學(xué)設(shè)計要求非常高,符合隔振,隔聲,消聲,吸聲,安全,環(huán)保,在保證隔音量的同時***大化提升空間使用面積。
2 技術(shù)參數(shù)及說明
(1)名稱:測聽室
(2)數(shù)量:1臺
(3)規(guī)格:長X寬X高(單位:mm)
外尺寸:3200mmX2400mmX2500mm(不含通風(fēng)系統(tǒng))
內(nèi)尺寸:2700mmX1900mmX2000mm
(4)工期:自收到預(yù)付款之日起25個工作日內(nèi)完成。
(5)產(chǎn)品說明:
結(jié)構(gòu):主體六面體,模塊結(jié)構(gòu),結(jié)構(gòu)之間采用搭接口及緊鎖裝置;設(shè)計整體為雙“懸浮”結(jié)構(gòu)式多層材料復(fù)合隔聲結(jié)構(gòu),具有隔聲,隔振,吸聲,換氣,防潮,安全等功能。
墻體: 雙層墻體結(jié)構(gòu),1.2mm鍍鋅鋼板噴塑,16mm防潮隔音板,復(fù)合隔聲墻體,鋼木結(jié)構(gòu),墻體厚度250mm,模塊拼裝組合式,可拆卸重裝。
減振:采用橡膠阻尼減振墊串聯(lián)方式,具有優(yōu)良的隔振和耐用性能。
隔音門:雙磁控“聲閘”隔音門2套,階梯式結(jié)構(gòu)。
隔音觀察窗:采用***雙層中空隔音窗技術(shù),透光好,隔聲性能指數(shù)高。
通風(fēng)消聲系統(tǒng):阻抗式復(fù)合通風(fēng)消聲器,超靜音風(fēng)機,強制送風(fēng)導(dǎo)入設(shè)計,***進、出風(fēng)口,
室內(nèi)吸聲內(nèi)飾:采用鋁合金沖孔鋁扣板(尺寸:600mmX600mm),使用輕鋼龍骨固定,內(nèi)填充玻璃棉。
室內(nèi)地面表面處理:環(huán)保隔音地毯,美觀,方便更換。
室內(nèi)電源照明系統(tǒng):AC220V接入,高亮LED吸頂燈,無干擾;配置照明,通風(fēng)換氣開關(guān),插座。
3 設(shè)計標準及依據(jù)
(1)《城市區(qū)域環(huán)境噪聲標準》(GB3096-93);
(2)《民用建筑隔聲設(shè)計規(guī)范》(G***118-2010);
(3)《室內(nèi)空氣質(zhì)量標準》(GB/T18883—2002);
(4)《建筑設(shè)計防火規(guī)范》(GBJ16—87)(2001年版);
(5)《電氣裝置安裝工程電氣照明裝置施工及驗收規(guī)范》(GB 50259—96);
(6)《民用建筑工程室內(nèi)環(huán)境污染控制規(guī)范》G***325—2010;
(7)符合國標GB/T7583標準。
4 方案設(shè)計
測聽室安裝在大樓,對于此區(qū)域位置,腳步聲密集,整個樓層都有多個聲源在振動,聲能密布,而且非穩(wěn)態(tài),這就要求隔聲,消聲,減振一體化設(shè)計。
在隔聲減振工程中,減少對內(nèi)噪聲的主要方式是在噪聲傳導(dǎo)路徑上增加阻尼構(gòu)造,更重要的是處理好空氣傳聲,阻隔聲波激勵測聽室表面形成的結(jié)構(gòu)聲。由于人員密集,腳步振動產(chǎn)生的聲音也會影響測聽室的***終隔音效果,所以本項目測聽室的結(jié)構(gòu)采用“懸浮”結(jié)構(gòu)式的施工方法,達到隔聲和隔振的雙重目標。
4.1墻體隔聲設(shè)計
環(huán)境聲壓級通常在峰值時會更高,為了達到測試時隔音效果,墻體采用相同的復(fù)合墻體鋼木隔聲結(jié)構(gòu),墻采用雙層16mm厚低密度高強度隔音板制造,墻體厚度為100mm,內(nèi)填充50mm厚48k玻璃棉(歐文斯科寧),外表面粘貼1.2mm厚脫脂,噴塑處理的鍍鋅鋼板,雙層墻體結(jié)構(gòu),雙層墻體之間留有50mm的空腔。
測聽室內(nèi)壁加裝輕鋼龍骨,沖孔鋁扣板作為內(nèi)飾材料,中間填充多孔吸聲材料。
4.2 地面隔聲隔振設(shè)計
由于測聽室安裝在大樓內(nèi),且人員密集,噪聲容易使測聽室產(chǎn)生振動,地面受迫振動對測聽室的影響僅次于隔墻,而且低頻能力為主,底板的設(shè)計既要隔聲又要隔振。通常地面做法對高頻的阻尼效果比較好,為了應(yīng)對地面的低頻振動,采取浮筑底板的做法:底板和墻體設(shè)計一樣,即復(fù)合隔聲底板;底板和樓板之間用橡膠阻尼減振墊串聯(lián)方式,能有效隔絕地板振動傳聲,具有優(yōu)良的隔聲,隔振和耐用性能,雙層底板之間也采用相同的減振方式,整個底板雙重減振。
4.3 室內(nèi)通風(fēng)消聲設(shè)計
測聽室出于檢測時對隔聲的高要求,通常采用密閉式的設(shè)計,一般只留供采光和觀察用的隔音窗,隔音門也是隔聲密閉的;為了營造一個舒適的檢測環(huán)境,保持良好的空氣質(zhì)量,測聽室的良好的通風(fēng)換氣系統(tǒng)是必不可少的。
我公司采用阻抗式消聲器,是一個具有吸聲內(nèi)忖套,迷宮式通道結(jié)構(gòu),截面為矩形的直管,吸聲元件包括多層的吸聲材料和一層透聲護面,超靜音風(fēng)機,軟風(fēng)管道等附件,用軟風(fēng)管與消聲器上的預(yù)留進風(fēng)口相連接,強制進風(fēng),進風(fēng)管道密閉性能好;消聲器內(nèi)部采用阻性和抗性消聲結(jié)構(gòu),既能允許氣流順利通過,達到通風(fēng)換氣要求,又能有效的阻止或減弱噪聲的傳入。
測聽室安裝兩個通風(fēng)消聲器,單獨進風(fēng),出風(fēng)口。進風(fēng)口可接空調(diào)。
4.4 室內(nèi)吸聲內(nèi)飾設(shè)計
為了進一步提高測聽室的隔音效果,美化室內(nèi)環(huán)境,室內(nèi)的內(nèi)飾消聲也是不容忽視的環(huán)節(jié),內(nèi)飾材料我們采用***孔鋁扣板,與隔音墻體之間用輕鋼龍骨連接,扣板和墻體之間填充玻璃棉,既能有效的做到隔聲,消聲,又可以為室內(nèi)提供一個環(huán)保,美觀的環(huán)境。
4.5 隔音觀察窗的設(shè)計
觀察窗我公司采用自研發(fā)的雙層中空隔音窗,是一種良好的透光,隔熱,隔音,美觀適用,并可降低測聽室自重的新型建筑材料,它是用兩片5mm隔音玻璃,使用高密度高氣密性復(fù)合粘結(jié)劑,將兩塊隔音玻璃粘結(jié),金屬邊框固定,制成的***能隔音隔熱玻璃。
雙層中空隔音窗隔音量高,全頻段隔音效果顯著,低頻隔音效果好;特種加工工藝,密閉性好;造型美觀,安全可靠。
4.6 門的隔音設(shè)計
本項目中的門均需要采用隔音門,我公司采用雙磁控聲閘隔音門,隔音門墻體采用1.2mm厚的國際鍍鋅鋼板,隔音門墻體外表面鋼板經(jīng)過脫脂,磷化,噴塑處理(顏色客戶選擇),隔音門墻體內(nèi)夾層選用阻尼板,三層50mm厚玻璃棉,高強度隔音板,隔音門結(jié)構(gòu)為階梯式結(jié)構(gòu),閉合處采用雙通道磁性密封條,密閉性能好。
隔音門按照《工業(yè)企業(yè)噪聲控制標準》對隔音門設(shè)計的要求,其隔聲能力強,強度高,并且為了防止隔聲板產(chǎn)生振動,采取了特殊的防振處理,大大提高了隔聲效果。采用多次復(fù)合,特殊隔聲結(jié)構(gòu),密封可靠,開啟靈活。
4.7 室內(nèi)地面環(huán)保設(shè)計
室內(nèi)地面鋪設(shè)環(huán)保隔音地毯(400mmX400mm),美觀,經(jīng)濟,方便更換和清洗。
4.8 室內(nèi)照明設(shè)計
針對照明舒適問題,我公司借鑒了“間接照明”技術(shù),燈具使用LED吸頂燈,安裝時注重光源與受光面之間的距離,與頂棚之間的距離,室內(nèi)受光面也是采用的也是能夠理想反射光的裝飾面,使之在光線處理上,使之間接化,自然化,柔和華。
5 設(shè)計效果
在嚴格按照上述設(shè)計方案采取聲學(xué)處理措施后,測聽室使用時,符合***GB/T7583標準,環(huán)境噪聲<55dB(A),測聽室室內(nèi)本底噪聲≤30dB(A)的聲學(xué)要求。
6聲學(xué)材料性能
6.1高強度隔聲板
(1)厚度:16mm
(2)密度:1.3g/m3
(3)熱壓溫度:195-210℃,A類,阻燃,結(jié)構(gòu)均勻。
6.2橡膠阻尼減振墊
(1)厚度:20mm;
(2)優(yōu)點:固有頻率低,結(jié)構(gòu)簡單,使用方便,壓縮變形低,許可載荷高。
6.3玻璃棉
(1)歐文斯科寧玻璃棉
(2)厚度50mm,容重16kg/m3
(3)熱導(dǎo)率低,保溫絕熱,吸音性能好,耐腐蝕,化學(xué)性能穩(wěn)定。
7 主要材料明細表
材料名稱 規(guī)格說明
鍍鋅鋼板 1.2mm厚,脫脂,磷化,噴塑
高強度隔音板 1220*2440*16mm
阻尼控制板 現(xiàn)代&=3mm
玻璃棉 歐文斯科寧,50mm厚
橡膠阻尼減振墊 厚度20mm
隔音玻璃 5mm厚
磁性密封條 PV-s70/m80
照明 LED吸頂燈
電線 1.5-4mm2,二三芯
電源插座 五孔,二三插
開關(guān) 雙開
超靜音風(fēng)機 綠島風(fēng)
8 施工說明及驗收標準
我方施工符合JGJ73-91《建筑裝飾工程施工及驗收規(guī)范》***標準;貴公司可派人參加質(zhì)量把關(guān),監(jiān)理;為我方提供必要的施工方便。
工廠模塊化生產(chǎn),現(xiàn)場組裝,無二次裝修痕跡。
驗收標準:
達到***GB/T7583標準,符合環(huán)境噪聲<55 dB(A),測聽室室內(nèi)本底噪聲≤30dB(A)的聲學(xué)要求。
若工程驗收不合格,我方需對測聽室進行整改至合格為止,整改費用由我方全部***。
若需第三方檢測,出具檢測報告,檢測費用由貴公司承擔(dān)。
9 ***服務(wù)
保修期為1年,長期供應(yīng)零部件,保修期內(nèi)的維修費用由我司負責(zé),易損件免費更換期1年。
保修期由設(shè)備驗收合格正常使用之日起計算,保修期內(nèi)如設(shè)備出現(xiàn)故障,我司應(yīng)接到通知后24小時內(nèi)派技術(shù)人員前來維修。
質(zhì)保期內(nèi)如發(fā)生非人為情況下出現(xiàn)的破損,剝落,變形等現(xiàn)象或其他故障影響聲學(xué)效果或妨礙正常檢測工作的,可免費更換或維修相應(yīng)的聲學(xué)部件,在超出質(zhì)保期或人為損壞的情況下,按市價收取材料費或成本費用。
我公司24小時提供電話咨詢服務(wù),在出現(xiàn)一般情況的小故障,在問題不算復(fù)雜或?qū)δ承┘夹g(shù)問題存在疑問時可通過電話,傳真,EMAIL的指導(dǎo)方式解決問題。
保修期滿后,設(shè)備出現(xiàn)故障需要我司提供維修服務(wù)時,我司免費提供維修,只收取更換零部件成本費。