開關(guān)電源S-201系列
***格、高可靠 Low price and high reliability
105℃輸出電容器 105℃ output capacitor
***適用AC輸入電源 AC input power suitable for the world
效率高、工作溫度低 High efficiency and low operation temperature
軟啟動(dòng)電流、有效降低AC輸入沖擊 Soft-start current can reduce the AC input impact efficiency
有短路保護(hù)、過(guò)載保護(hù) With short-circuit and overload protection
體積小、重量輕 Compact size, light weight
100﹪滿負(fù)荷燒機(jī)測(cè)試 100﹪full-load burn-in test
內(nèi)裝EMI濾波器、紋波*** Installed with EMI filter, minimum w***e
型號(hào) Mode
性能 Performance |
S-201-5 |
S-201-7.5 |
S-201-12 |
S-201-13.5 |
S-201-15 |
S-201-24 |
S-201-27 |
S-201-48 |
|||||||
直流輸出電壓 DC output voltage |
5V |
7.5V |
12V |
13.5V |
15V |
24V |
27V |
48V |
|||||||
輸出電壓容差 Output voltage tolerance |
&plu***n;2﹪ |
&plu***n;1﹪ |
&plu***n;1﹪ |
&plu***n;1﹪ |
&plu***n;1﹪ |
&plu***n;1﹪ |
&plu***n;1﹪ |
&plu***n;1﹪ |
|||||||
額定輸出電流 Rated output current |
42A |
26.5A |
16.5A |
14.7A |
13A |
8.3A |
7.4A |
4.2A |
|||||||
輸出電流范圍 Output current range |
0~40A |
0~26.5A |
0~16.5A |
0~14.7A |
0~13A |
0~8.3A |
0~7.4A |
0~4.2A |
|||||||
紋波及噪音 Ripple and noise |
75mVp-p |
75mVp-p |
75mVp-p |
75mVp-p |
75mVp-p |
75mVp-p |
100mVp-p |
100mVp-p |
|||||||
進(jìn)線穩(wěn)定度 Inlet stability |
&plu***n;0.5﹪ |
&plu***n;0.5﹪ |
&plu***n;0.5﹪ |
&plu***n;0.5﹪ |
&plu***n;0.5﹪ |
&plu***n;0.5﹪ |
&plu***n;0.5﹪ |
&plu***n;0.5﹪ |
|||||||
負(fù)載穩(wěn)定度 Load stability |
&plu***n;1﹪ |
&plu***n;1﹪ |
&plu***n;0.5﹪ |
&plu***n;0.5﹪ |
&plu***n;0.5﹪ |
&plu***n;0.5﹪ |
&plu***n;0.5﹪ |
&plu***n;0.5﹪ |
|||||||
直流輸出功率 DC output power |
200W |
198.75W |
198W |
198.45W |
195W |
199.2W |
199.8W |
201.6W |
|||||||
效率 Efficiency |
78﹪ |
79﹪ |
83﹪ |
83﹪ |
83﹪ |
83﹪ |
83﹪ |
84﹪ |
|||||||
直流電壓可調(diào)范圍 Adjustable range for DC voltage |
4.5-5.6V |
6&plu***n;9V |
10&plu***n;13.2V |
12-15V |
13.5-18V |
20-26.4V |
26-32V |
41-56V |
|||||||
輸入電壓范圍 AC input voltage range |
90~132VAC/180~264VAC由開關(guān)選擇47~63Hz; 254~370VDC |
||||||||||||||
輸入電流 Input current |
3.6A/115V 1.8A/230V |
||||||||||||||
沖擊電流 AC dash current |
25A/115V 50A/230V |
||||||||||||||
漏電流 Leakage current |
<3.5mA/240VAC |
||||||||||||||
過(guò)載保護(hù) Overload protection |
105﹪~150﹪類型:切斷輸出 復(fù)位:自動(dòng)*** 105﹪~150﹪ Type: pulsing hiccup shutdown reset: auto recovery |
||||||||||||||
過(guò)電壓保護(hù) Over-voltage protection |
5.75-6.75V |
9.4-10.9V |
13.8-16.2V |
15.5-18.2V |
18-21V |
27.6-32.4V |
33.7-39.2V |
57.6-67.2V |
|||||||
高溫保護(hù) High-temperature protection |
ERH3≥90℃輸出關(guān)閉 |
||||||||||||||
溫度系數(shù) Temperature coefficient |
&plu***n;0.03﹪/℃(0~50℃) |
||||||||||||||
啟動(dòng)、上升、保持時(shí)間 Startup .rise .retention time |
200ms, 100ms, 20ms |
||||||||||||||
抗震性 Vibration |
10~500Hz, 2G 10min/1周期,時(shí)長(zhǎng)60分鐘,各軸 10~500Hz, 2G 10min/1 cycle , Period for 60 min , Each axes |
||||||||||||||
耐壓性 With standard voltage |
輸入輸出間:1.5KvAC輸入與外殼: 1.5KvAC輸出與外殼: 0.5KvAC Input and output internal :1.5KvAC input and enclosure : 1.5KvAC output and enclosure: 0.5KvAC |
||||||||||||||
隔離電阻 Isolation resistance |
輸入輸出間: 輸入與外殼,輸出與外殼:500VDC/100MΩ Input and output internal: input and enclosure. Output and enclosure: 500VDC/100MΩ |
||||||||||||||
工作溫度、濕度 Working temperature and humidity |
-10℃~+60℃(參考輸出特***),20﹪~90﹪RH -10℃~+60℃(Refer to output derating curve,20﹪~90﹪RH |
||||||||||||||
存儲(chǔ)溫度、濕度 Store temperature and humidity |
-20℃~+85℃, 10%~95%RH |
||||||||||||||
外型尺寸 Overall dimension |
215×115×50mm |
||||||||||||||
重量 Weight |
0.9kgs |
||||||||||||||
安全標(biāo)準(zhǔn) Safety standa*** |
設(shè)計(jì)交付UL1950 Design refer to UL 1950 |
||||||||||||||
EMC標(biāo)準(zhǔn) EMC standa*** |
設(shè)計(jì)表示FCC部分15J條件 等級(jí)A Design refer to FCC Part15J class A |
||||||||||||||
備注: 1.以上參數(shù)測(cè)試條件為:230VAC輸入,額定負(fù)載,25℃ 70%Rh,溫度。 2.容差: 包括設(shè)定容差,線路穩(wěn)定度,負(fù)載穩(wěn)定度。 3.紋波測(cè)試:20MHz用“A12”雙絞線,中斷用0.1uF&47uF電容器短路。 4.進(jìn)線電壓穩(wěn)定度測(cè)試:滿負(fù)載時(shí)進(jìn)線***低電壓到***高電壓。 5.負(fù)載穩(wěn)定度測(cè)試:負(fù)載從0%到100%。 6.C3、4、32必須拆除。 Note : 1. The testing condition for the parameter above is : 230VAC input ,rated load, 25℃ 70%Rh. Temperature. 2. Error, include the setting error, line stability and load stability . 3. W***e test: adopt “A12” double wire for 20MHz, and 0.1UF & 47UF capacitor short-circuit for interrupting. 4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: The load is from 0% to100% 6.C3、4、32 must be knocked down. |