国产操逼视频,无码人妻AV免费一区二区三区 ,免费a级毛片无码无遮挡,国产精品一区二区久久精品

企業(yè)資質(zhì)

深圳市優(yōu)爾檢測(cè)技術(shù)有限公司

普通會(huì)員9
|
企業(yè)等級(jí):普通會(huì)員
經(jīng)營模式:
所在地區(qū):廣東 深圳
聯(lián)系賣家:
手機(jī)號(hào)碼:
公司官網(wǎng):ycct.com.cn
企業(yè)地址:
本企業(yè)已通過工商資料核驗(yàn)!
企業(yè)概況

優(yōu)爾國際簡介深圳市優(yōu)爾檢測(cè)技術(shù)有限公司是中國最具權(quán)威性的安規(guī)認(rèn)證咨詢檢測(cè)機(jī)構(gòu),總部設(shè)在深圳。在中國,優(yōu)爾國際是唯一一家在“咨詢、申請(qǐng)、儀器、檢測(cè)、生產(chǎn)、培訓(xùn)、審核”等七方面為國內(nèi)外企業(yè)提供著長期而友好服務(wù)的認(rèn)證咨詢檢測(cè)機(jī)構(gòu)!優(yōu)爾國際目前在中國擁有電線電纜測(cè)試室驗(yàn)室、燃燒實(shí)驗(yàn)室、線路板實(shí)驗(yàn)室、標(biāo)簽實(shí)驗(yàn)......

HWI測(cè)試,ABS塑膠顆粒UL認(rèn)證

產(chǎn)品編號(hào):1027307758                    更新時(shí)間:2019-10-30
價(jià)格: ¥1.00

深圳市優(yōu)爾檢測(cè)技術(shù)有限公司

  • 主營業(yè)務(wù):電線電纜、線路板、標(biāo)簽UL/CSA
  • 公司官網(wǎng):ycct.com.cn
  • 公司地址:

聯(lián)系人名片:

聯(lián)系時(shí)務(wù)必告知是在"產(chǎn)品網(wǎng)"看到的

產(chǎn)品詳情

Flammability

Materials may be classified based on burning tests conducted in accordance with ANSI/UL 94, "Tests for Flammability of Plastic Materials for Parts in Devices and Appliances," ANSI/UL 1694, "Tests for Flammability of ***all Polymeric Component Materials," and ANSI/UL 723, "Test for Surface Burning Characteristics of Building Materials."
ANSI/UL 94 ***all-scale test data does not pertain to building materials, furnishings and related contents, and is intended solely for determining the flammability of plastic materials used in the components and parts of end-use-product devices and appliances, where the acceptability of the combination is determined by UL.
TEST NAME (per ANSI/UL 94)

Horizontal Burning Test
20 mm Vertical Burning Test Thin Material Vertical Burning Test Horizontal Burning Foamed Material Test 
500 Watt (125 mm) Vertical Test
Flame Rating Hierarchy — V-0 VTM-0 — More Severe 5VA
— V-1 VTM-1 HF-1 ↑


— V-2 VTM-2 HF-2 5VB
HB — — HBF Less Severe
Thermal Endurance

The materials covered by this program h***e been investigated with respect to thermal endurance of certain critical properties. The investigation was performed as part of a long-term thermal-aging program or based on historical record in accordance with ANSI/UL 746B, "Polymeric Materials - Long Term Property Evaluati***." The temperature below which a class of critical property will not be unacceptably compromised through chemical thermal degradation, over the reasonable life of an electrical product (relative to a reference material h***ing a confirmed, acceptable corresponding performance) is defined as the Relative Thermal Index (RTI). More than one RTI may be appropriate for a given material depending on the property requirements for a given application. In certain cases, higher temperatures are permitted if so specified by the end-use-product standard.
RTI Elec — Electrical RTI, associated with critical insulating properties.
RTI Mech Imp — Mechanical Impact RTI, associated with critical impact resistance, toughness, elongation and flexibility properties.
RTI Mech Str — Mechanical Strength (Mechanical without Impact) RTI, associated with critical mechanical strength and structural integrity where impact resistance, resilience and flexibility may not be essential.
Resistance to Ignition and Tracking Properties

Performance may be investigated with respect to electrical track resistance, ability to resist ignition from electrical sources, and other electrical properties. In order to ***oid an excessive level of implied precision and bias, material performances for several tests are recorded as Performance Level Categories (PLC), based on the mean test results (rather than recording the exact numerical results), as indicated in the table following the test description.
Hot-wire Ignition (HWI; ASTM D3874, IEC 60695-2-20) — Performance is expressed as the mean number of seconds needed to ignite standard specimens (if the material ignited). An HWI PLC 0 may be due to all the test specimens melting away without any ignition.
HWI Range
Mean Ignition Time (in sec) Assigned
PLC
120 and longer 0
60 through 119 1
30 through 59 2
15 through 29 3
7 through 14 4
Less than 7 5
High-current-arc Ignition (HAI; ANSI/UL 746A) — Performance is expressed as the number of arc-rupture exposures (standardized as to electrode type and shape and electric circuit) that are necessary to ignite a material when they are applied at a standard rate on the surface of the material.
HAI Range
Mean Number of Arcs
to Cause Ignition Assigned
PLC
120 and greater 0
60 through 119 1
30 through 59 2
15 through 29 3
Less than 15 4
High-voltage-arc Tracking Rate (HVTR; ANSI/UL 746A) — Denoted as the rate, in mm/min, that a tracking path can be produced on the surface of the material under standardized test conditi***. A notation is made if ignition on the material takes place. The results of testing the nominal 3 mm thickness are c***idered representative of the material's performance in any thickness.

 

代理范圍:

(一)水平燃燒測(cè)試,94HB,并指導(dǎo)前期打樣送測(cè);

(二)垂直燃燒測(cè)試,94V-2,94V-1,94V-0,并指導(dǎo)前期打樣送測(cè);

詳詢Sunny陶13913142465 ***1822971259


 

深圳市優(yōu)爾檢測(cè)技術(shù)有限公司電話:傳真:聯(lián)系人:

地址:主營產(chǎn)品:電線電纜、線路板、標(biāo)簽UL/CSA

Copyright ? 2024 版權(quán)所有: 產(chǎn)品網(wǎng)店鋪主體:深圳市優(yōu)爾檢測(cè)技術(shù)有限公司

免責(zé)聲明:以上所展示的信息由企業(yè)自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布企業(yè)負(fù)責(zé)。產(chǎn)品網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。